Working principle of pilot piston solenoid valve

Dec 05, 2019

The working principle of the pilot piston solenoid valve is mainly divided into two types: normally open (powered off) and normally closed (powered on).

It works as follows:

Normally closed: When the coil is energized, the solenoid core is attracted, the pressure relief hole is opened, the main piston medium pressure is pushed, the main valve port is opened, and the medium is circulated. When the coil is de-energized, the main valve port is closed and the medium is cut off.

Normally open: When the coil is energized, the solenoid core is closed, the pressure relief hole is closed, the main piston is pushed by the medium pressure, the main valve port is closed, and the medium is cut off. When the coil is de-energized, the main valve port opens and the medium flows.


Note:

1. Pilot-operated piston solenoid valve requires that the medium passing through the solenoid valve must have pressure (no medium is not suitable for this type of valve). The solenoid valve on our side must ensure that the medium has a pressure of 0.1 kg to be normal. jobs.

2. There are two sources of force for pilot piston solenoid valve to open the main piston. One is the magnetic force generated after power is applied, and the second is the pressure of the medium.