The high-pressure solenoid valve is actually a combination of an electromagnetic induction pressure regulating valve and a pneumatic filter valve. The electromagnetic induction pressure regulating valve controls the opening and closing of the pneumatic filter valve to complete the sewage treatment and pressure transformation of the refrigeration compressor.

When the solenoid valve is connected to the power supply, the magnetic field force promotes the control valve core to press against the pressure regulating valve seat to complete the sealing between the two. At this time, the reduced steam enters the pneumatic valve core according to a small round hole on the pneumatic valve core. At the top, high pressure is generated here to promote the pneumatic valve core to press against the pneumatic valve seat to complete the closing of the pneumatic valve.

When the solenoid valve trips, the magnetic field force subsides, and the high-pressure steam at the top of the pneumatic valve core pulls open the control valve core and is discharged. At this time, the high-pressure steam at the bottom of the pneumatic valve core promotes the pneumatic valve core to leave the pneumatic valve seat. The solenoid valve is opened to complete the sewage treatment.

According to the time controller, the solenoid valve is controlled by the power connection and the interval time and delay time of the trip to complete the automatic closing and opening of the solenoid valve.